TDS · ENZ005
Technical Data Sheet – Intensa Evity 200 T
Technical Data Sheet for Intensa Evity 200 T, issued by Handymade.
- Product code
- ENZ005
- Date of issue
- 3 November 2026
- Status
- Validproduct document without time limit
01General identification data
| Parameter | Value |
|---|
| Product colour | White |
| Processing method | Fermentation |
02Formulation parameters
| Parameter | Value | Unit |
|---|
| Free from | parabens | |
| Function in formulation | Active ingredient, Builder | |
| Recommended usage rate | 1,5 – 5 | % |
| Recommended formulation pH range | 7,0 – 10,5 | |
| Solubility | Water-soluble | |
| Application type | Rinse-off | |
| Effects | Cleansing | |
03Sustainability and certifications
| Parameter | Value |
|---|
| Natural Origin Index (NOI ISO 16128) | 0,95 |
04Regulation and Safety
| Parameter | Value |
|---|
| Product CMR classification | The product is not classified as carcinogenic, mutagenic, or toxic to reproduction (CMR) according to Regulation (EC) No 1272/2008. |
| CLP classification | The substance is classified according to Regulation (EC) No 1272/2008 (CLP) and contains hazardous substances. Detailed information on composition, classification and safe handling is provided in the Safety Data Sheet (SDS), which is available on request. |
| CMR ingredient content | The product does not contain any ingredients classified as carcinogenic, mutagenic, or toxic to reproduction (CMR). |
| Pictograms | GHS05 Corrosive (skin, materials), GHS08 Serious health hazard (chronic) |
| SVHC | The product is neither listed as a Substance of Very High Concern (SVHC) nor does it contain any material listed as an SVHC according to Article 59 of Regulation (EC) No 1907/2006 (REACH). |
The information contained in this document is provided in good faith and to the best of our current knowledge. It is provided without warranty and does not constitute a guarantee of the product's suitability for any particular purpose.
The customer bears sole responsibility for verifying the suitability, safety and compliance of the product for the intended use and final application. Where necessary, appropriate tests should be carried out before use.
All information is considered accurate as at the date of issue; however, product data may change. We therefore recommend that customers keep their technical documentation up to date.
This document may not be reproduced, disclosed or distributed, in whole or in part, without the prior written consent of Handymade s.r.o.