TDS · FT215
Technical Data Sheet – Liquid Glycerin Dye, Violet
Technical Data Sheet for Liquid Glycerin Dye, Violet, issued by Handymade.
- Product code
- FT215
- Date of issue
- 30 October 2026
- Status
- Validproduct document without time limit
01General identification data
| Parameter | Value |
|---|---|
| HS code | 32129000 |
| Country of origin | European Union |
| Processing method | Blending |
| Storage conditions | Protect from moisture, Keep container tightly closed |
02Formulation parameters
| Parameter | Value |
|---|---|
| Free from | parabens |
| Formulation phase | Water phase, Post-addition |
| Function in formulation | Colorant |
| Compatibility | Anionic surfactants, Non-ionic surfactants, Neutral pH |
| Application area | Body |
| Application | Soaps, Bath bombs and salts, Shower and bath products |
| Application type | Rinse-off |
03Regulation and Safety
| Parameter | Value |
|---|---|
| Allergens | The product does not contain any of the fragrance allergens listed in Annex III to Regulation (EC) No 1223/2009, as amended, including Commission Regulation (EU) 2023/1545. |
| CITES | The product is not derived from endangered species listed in the CITES Appendices and therefore does not require CITES certification. |
| CMR ingredients | 1,4-Dioxane (123-91-1) |
| CLP classification | The substance is classified according to Regulation (EC) No 1272/2008 (CLP) and contains hazardous substances. Detailed information on composition, classification and safe handling is provided in the Safety Data Sheet (SDS), which is available on request. |
| CMR ingredient content | The product contains traces of a substance classified as CMR as a technological impurity below the classification threshold of the mixture (0.1%). |
| Parabens | The product is free from parabens. |
| Pictograms | GHS07 Irritant, sensitisation, harmful |
| REACH status | The product is compliant with Regulation (EC) No 1907/2006 (REACH). |
| SVHC | Product contains a substance on the SVHC list as a process impurity at a concentration below 0.1% (w/w), below the obligation threshold under Art. 33 of Regulation (EC) No 1907/2006 (REACH). |
| Animal testing | The product has not been tested on animals for cosmetic purposes by the manufacturer or by third parties acting on its behalf. |
| UFI number | RUT0-C0P5-M00W-XTMQ |
The information contained in this document is provided in good faith and to the best of our current knowledge. It is provided without warranty and does not constitute a guarantee of the product's suitability for any particular purpose. The customer bears sole responsibility for verifying the suitability, safety and compliance of the product for the intended use and final application. Where necessary, appropriate tests should be carried out before use. All information is considered accurate as at the date of issue; however, product data may change. We therefore recommend that customers keep their technical documentation up to date. This document may not be reproduced, disclosed or distributed, in whole or in part, without the prior written consent of Handymade s.r.o.