TDS · SV020
Technical Data Sheet – KeraSoy Container 4130, candle wax
Technical Data Sheet for KeraSoy Container 4130, candle wax, issued by Handymade.
- Product code
- SV020
- Date of issue
- 22 November 2026
- Status
- Validproduct document without time limit
01General identification data
| Parameter | Value |
|---|
| HS code | 15162096 |
| Product colour | White |
| Country of origin | United Kingdom |
| Grade | Technical grade |
| Processing method | Hydrogenation, Blending |
| Origin of product | Vegetable |
| Storage conditions | Store in a dry and clean environment, Store in a cool place, Protect from direct sunlight, Protect from moisture, Keep container tightly closed, Store in the original container, Protect from heat |
02Formulation parameters
| Parameter | Value | Unit |
|---|
| Free from | paraffin | |
| Formulation phase | Oil phase | |
| Maximum fragrance load | 10 – 12 | % |
| Recommended processing temperature | 80 – 85 | °C |
| Application | Candles | |
| Solubility | Water-insoluble, Oil-soluble | |
03Sustainability and certifications
| Parameter | Value |
|---|
| Biodegradability | Readily biodegradable |
| Certifications and declarations | Vegan |
| Natural Origin Index (NOI ISO 16128) | 1,00 |
04Regulation and Safety
| Parameter | Value |
|---|
| Allergens | The product does not contain any of the fragrance allergens listed in Annex III to Regulation (EC) No 1223/2009, as amended, including Commission Regulation (EU) 2023/1545. |
| CITES | The product is not derived from endangered species listed in the CITES Appendices and therefore does not require CITES certification. |
| Ethylene oxide | Ethylene oxide is not used in the production process of this product. |
| CLP classification | This product is not classified as hazardous according to Regulation (EC) No 1272/2008 (CLP), and therefore a Safety Data Sheet (SDS) is not required for it under Article 31 of Regulation (EC) No 1907/2006 (REACH). |
| Microplastics (EU 2023/2055) | This product does not contain intentionally added synthetic polymer microparticles pursuant to Commission Regulation (EU) 2023/2055. |
The information contained in this document is provided in good faith and to the best of our current knowledge. It is provided without warranty and does not constitute a guarantee of the product's suitability for any particular purpose.
The customer bears sole responsibility for verifying the suitability, safety and compliance of the product for the intended use and final application. Where necessary, appropriate tests should be carried out before use.
All information is considered accurate as at the date of issue; however, product data may change. We therefore recommend that customers keep their technical documentation up to date.
This document may not be reproduced, disclosed or distributed, in whole or in part, without the prior written consent of Handymade s.r.o.